Peppol BIS 3.0 validator
Checks a UBL invoice or credit note against the business rules of Peppol BIS Billing 3.0.21: the European standard EN 16931 (calculations, VAT categories, code lists, UBL syntax) and the Peppol rules on top. Each problem is listed with its rule ID, its severity, an explanation and its place in the file. The file is read in your browser and never uploaded.
Drag and drop a UBL XML file here, or choose one below.
One .xml file, up to 20 MB. Read in your browser, never uploaded.
Choose a UBL invoice or credit note, or try the example, to check it against the Peppol BIS 3.0 rules.
What this validator checks
1,036 of the 1,042 Peppol BIS Billing 3.0.21 rules that apply to every invoice (EN 16931 and Peppol). Not checked: the 102 national rules (DE, DK, GR, IS, IT, NL, NO, SE) and the UBL XML schema (XSD). Not the official validator: your access point has the final word.
How it works
Before sending a Peppol invoice, an access point checks it against two official rule sets, published as Schematron files: EN 16931 bound to UBL, maintained by CEN (rules BR-*, BR-CO-*, BR-DEC-*, BR-CL-*, UBL-SR-*, UBL-DT-*, UBL-CR-*), and the Peppol BIS Billing rules (PEPPOL-EN16931-*, PEPPOL-COMMON-*). A file with a fatal error is rejected.
This validator applies those rules with its own code, written from the official files of Peppol BIS Billing 3.0.21 (CEN validation artefacts 1.3.16). It checks 1,036 of the 1,042 rules that apply to every Peppol invoice. The other 6 can never fail, because their official test is always true, so there is nothing to check. The 102 national rules, which apply only to invoices from or to Germany, Denmark, Greece, Iceland, Italy, the Netherlands, Norway or Sweden, are not checked.
Its results were compared with those of the official Schematron, run with the reference XSLT processor, on the official examples and test files and on thousands of modified invoices: same rules, same number of findings, same places. It is still not the official validator. For a binding answer, use your access point's validation.
What it does not check: the UBL 2.1 XML schema (XSD), so element order, unknown elements and data types the schema would reject are reported only when a rule covers them; whether identifiers exist (VAT numbers, Peppol participant IDs); and whether the invoice is right for your tax situation. When the official Schematron stops with a processing error (for example, an element repeated where only one is expected), this validator still reports the rules it can check.
Fatal errors make the invoice invalid: an access point rejects it. Warnings do not block sending; they point to elements EN 16931 does not use, which the receiver may ignore, or to values that should be corrected.
Example
Click “Try an example” to load a fictional invoice from a Luxembourg supplier containing four deliberate mistakes.
The result is “Invalid”, with 3 fatal errors and 1 warning.
BR-CO-15: the total with VAT is 1,609.00 instead of 1,382.00 + 227.66 = 1,609.66. PEPPOL-EN16931-R120: on line 2, 4 × 13.00 + 2.00 ≠ 52.00. PEPPOL-EN16931-R003: neither a buyer reference nor a purchase order reference.
The warning, UBL-CR-005, points to a UUID element: EN 16931 does not use it, so the receiver may ignore it. Each rule ID links to its official description.
Frequently asked questions
Does a valid result mean my invoice will be accepted?
It means none of the 1,036 rules checked here failed. An access point also validates the XML schema, and invoices from or to some countries must pass national rules this tool doesn't check. Luxembourg has no national rules in Peppol BIS Billing, so for an invoice between two Luxembourg companies the remaining gap is the XML schema.
Is my invoice uploaded anywhere?
No. The file is read by your browser and checked on your device; nothing is sent to a server and nothing is kept once you close or reload the page. Only your chosen language is stored, locally.
What is the difference between an error and a warning?
A fatal error breaks a rule the invoice must follow: Peppol access points reject the file. A warning does not block sending; most warnings flag UBL elements that EN 16931 does not use and that the receiver may ignore.
Which files does it accept?
UBL 2.1 invoices and credit notes (Peppol BIS Billing 3.0), as an .xml file of up to 20 MB. A Factur-X or ZUGFeRD file uses the CII format instead: open it with the Factur-X reader.
Which version of the rules does it use?
Peppol BIS Billing 3.0.21, which includes the CEN EN 16931 validation artefacts 1.3.16. The rules are updated when OpenPeppol publishes a new release.